THERMAL POWER

Knürr DCD

[:en]Knürr DCD is an air-water heat exchanger that is integrated into the rear door of a server cabinet. The heat exchanger serves to absorb heat loads from server racks of up to 50 kW. Knürr DCD is configurable with Knürr DCM cabinets or can be mounted to other vendor cabinets. The design of the heat exchanger permits an increase in the chilled water temperature.[:en]Knürr DCD is an air-water heat exchanger that is integrated into the rear door of a server cabinet. The heat exchanger serves to absorb heat loads from server racks of up to 50 kW. Knürr DCD is configurable with Knürr DCM cabinets or can be mounted to other vendor cabinets. The design of the heat exchanger permits an increase in the chilled water temperature.[:]

Liebert AFC, Adiabatic

[:el]The Liebert AFC combines the outstanding levels of energy efficiency allowed by freecooling together with the endless availability guaranteed by the compressor back up (available both with multi-scroll or screw compressors) and the highly efficient adiabatic wet pad system. The pad humidifies the air entering the freecooling and condensing coils, consequently increasing freecooling operation. The unit is designed to ensure the availability of the 100% even in the most critical conditions.​​​​[:en]Liebert AFC combines the outstanding levels of energy efficiency allowed by freecooling together with the endless availability guaranteed by the compressor back up (available both with multi-scroll or screw compressors) and the highly efficient adiabatic wet pad system. The latter humidifies the air entering the freecooling and condensing coils, consequently increasing freecooling operation. The unit is thus designed to guarantee 100% cooling availability even under the most critical conditions.[:]

Liebert CRV, Row-based

[:el]A self-contained data center cooling unit that is ideally suited and designed for cooling server rack cabinets in small and medium data centers. Liebert CRV features the iCOM Control and a digital scroll compressor, for high reliability and optimized data center heat management.​​​​[:en]A self-contained data center cooling unit that is ideally suited and designed for cooling server rack cabinets in small and medium data centers. Liebert CRV features the iCOM Control and a digital scroll compressor, for high reliability and optimized data center heat management.​​​​[:]

Liebert DCL, Modular

[:el]The Liebert DCL is the Thermal Management unit for lateral attachment to server cabinets offering a wide range of features designed specifically for data center applications. The unit is available in two different architectures, closed or hybrid loop, and in multiple combinations of up to four server racks to match any customer needs.​​​​​[:en]The Liebert DCL is the Thermal Management unit for lateral attachment to server cabinets offering a wide range of features designed specifically for data center applications. The unit is available in two different architectures, closed or hybrid loop, and in multiple combinations of up to four server racks to match any customer needs.​​​​​[:]

Liebert EFC, Evaporative

[:en]The system includes indirect air-to-air heat exchange and evaporative cooling technology all in one footprint. The Liebert EFC is capable of reducing air temperatures by leveraging on the evaporative cooling principle. Through this technology, the Liebert EFC can thus achieve pPUE levels of 1.03 ensuring top energy efficiency, as well as minimized operating costs.[:en]The system includes indirect air-to-air heat exchange and evaporative cooling technology all in one footprint. The Liebert EFC is capable of reducing air temperatures by leveraging on the evaporative cooling principle. Through this technology, the Liebert EFC can thus achieve pPUE levels of 1.03 ensuring top energy efficiency, as well as minimized operating costs.[:]

Liebert FCM

[:en]Liebert® FCM represents the most complete direct freecooling module specifically designed to control the environmental conditions of technological rooms as well as of Telecom network sites. [:]

Liebert HPC-S, Free

[:el]Air-Cooled, freecooling and adiabatic freecooling chillers designed for the efficient cooling of small data centers. [:]

Liebert HPC-W, Water-Cooled

[:el]The Liebert HPC-W is a water-cooled chiller (600-2100kW) with fixed-speed screw compressors. The different sound emission versions offer the possibility to choose standard or unrivaled low noise level.[:]

Liebert HPF, standalone

[:en]Liebert® HPF represents the most complete indoor self-contained cooling system specifically designed to control the environmental conditions of technological or industrial rooms as well as of Telecom network sites. [:]

Liebert HPW

[:en]High Performance Wall-mount Cooling Solution for Telecom Mobile Applications Liebert HPW is the ultimate cooling system ideal for Mobile Telecom Network remote access node in shelters and containers. The Liebert HPW units are packaged, outdoor, wall-mount cooling solutions, with the traditional upflow or the innovative downflow air delivery solutions.[:]

Liebert PCW, Unit

[:el]The Liebert PCW is the ideal chilled water cooling unit, providing an efficient solution for data center and server room air conditioning. This water cooling system is available in a wide variety of configurations and capacities, ranging from 200 kW to 6 MW.[:en]Liebert PCW is the ideal chilled water cooling unit, providing an efficient solution for data center and server room air conditioning. This water cooling system is available in a wide variety of configurations and capacities, ranging from 200 kW to 6 MW.[:]

Liebert PDX, Direct

[:en]The Liebert PDX direct expansion large room cooling unit is equipped with the most advanced industry cooling system technology, which allows the unit to provide thermal management efficiency for data centers and server rooms. [:]