Socomec DELPHYS GP, 160-1000 kVA

[:en]

High-performance protection without compromise.
Three-phase UPS with power from 160 to 1000 kVA.

[:en]

High-efficiency protection without compromise.
Three phase UPS from 160 to 1000 kVA.

[:]

Share it:

[:en]The solution for:
• Data centers.
• Telecommunications.
• Health Sector.
• Service sector.
• Infrastructure.
• Industrial applications.

 

Advantages:
• Offers the highest performance on the market using VFI – Double Conversion Mode, the only UPS function that ensures complete load protection against all network quality problems.
• Highly efficient output independently tested and verified by an international certification body across a wide range of load and voltage operating conditions.
• Extremely high efficiency in VFI mode is provided by an innovative topology (3-level technology) developed for all Green Power UPS series.

 

Full rated power:
• No power degradation when delivering the latest generation of servers (driver or unity power factor).
• Real full power, according to IEC 62040: kW = kVA (unity power factor design) means 25% more active power compared to the older UPS.
• Also suitable for driving loads with a power factor below 0.9 without noticeable reduction.

 

Significant cost savings (TCO):
• Maximum energy savings thanks to 96% efficiency in true double conversion mode: 50% energy savings compared to the older UPS, offers significant energy savings.
• Performance up to 99% with FAST ECOMODE.
• UPS “self-help” with energy saving.
• Energy saving mode to improve overall performance in parallel systems.
• kW = kVA means maximum available power with the same UPS rating: no over-specification costs and consequently less €/kW.
• Advanced infrastructure cost optimization (sources and distribution), thanks to the high-efficiency IGBT rectifier.
• Battery life and performance:
– long-life battery,
– Very wide input voltage and frequency acceptance, without using a battery.
• EBS (Expert Battery System) charging management improves battery life.
• BCR (Re-Injection Capacity Battery) removes the limitations of using an additional load bank for battery discharge testing: it consists of re-injecting the energy stored in the batteries into other applications.

 

UPS model Dimensions (WxHxD) Weight
Delphis GP, 160 700 x 1930 x 800 mm 470 kg
Delphis GP, 200 1000 x 1930 x 700 mm 490 kg
Delphis GP, 250 1000 x 1930 x 950 mm 850 kg
Delphis GP, 320 1400 x 1930 x 800 mm 980 kg
Delphis GP, 400 1400 x 1930 x 800 mm 1000 kg
Delphis GP, 500 1600 x 1930 x 950 mm 1500 kg
Delphis GP, 600 2800 x 2060 x 950 mm 2300 kg
Delphis GP, 800 3510 x 2060 x 950 mm 2800 kg
Delphis GP, 1000 3910 x 2060 x 950 mm 3850 kg

 

DELPHYS-GP_CATALOGUE

 

[:en]The solution for:
• Data centers.
• Telecommunications.
• Healthcare sector.
• Service sector.
• Infrastructure.
• Industrial applications.

 

Advantages:
• Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that ensures total load protection against all mains quality problems.
• Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating conditions.
• Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power UPS ranges.

Full rated power:
• No power downgrading when supplying the latest generation of servers (leading or unity power factor).
• Real full power, according to IEC 62040: kW=kVA (unity power factor design) means 25% more active power available compared to legacy UPS.
• Suitable also for leading power factor loads down to 0.9 without apparent derating.
Significant cost savings (TCO):

• Maximum energy saving thanks to 96% efficiency in true double conversion mode: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill.
• Up to 99% efficiency with FAST ECOMODE.
• UPS "self-paying" with energy saving.
• Energy Saver mode for global efficiency improvement on parallel systems.
• kW=kVA means maximum power available with the same UPS rating: no overdesign cost and therefore less €/kW.
• Upstream infrastructure cost optimization (sources and distribution), thanks to high performance IGBT rectifier.
Extended battery life and performance:
– long-life battery,
– very wide input voltage and frequency acceptance, without battery use.
• EBS (Expert Battery System) charging management improves battery service life.
• BCR (Battery Capacity Re-injection) removes the constraints of using an additional load bank for the battery discharge test: it consists in re-injecting the energy stored in the batteries to other applications.

 

UPS Model Dimensions (WxHxD) Weight
Delphis GP, 160 700 x 1930 x 800 mm 470 kg
Delphis GP, 200 1000 x 1930 x 700 mm 490 kg
Delphis GP, 250 1000 x 1930 x 950 mm 850 kg
Delphis GP, 320 1400 x 1930 x 800 mm 980 kg
Delphis GP, 400 1400 x 1930 x 800 mm 1000 kg
Delphis GP, 500 1600 x 1930 x 950 mm 1500 kg
Delphis GP, 600 2800 x 2060 x 950 mm 2300 kg
Delphis GP, 800 3510 x 2060 x 950 mm 2800 kg
Delphis GP, 1000 3910 x 2060 x 950 mm 3850 kg

 

DELPHYS-GP_CATALOGUE

 

[:]

Επιπλέον πληροφορίες

UPS Manufacturer

UPS power

, ,

UPS Series

Socomec DELPHYS GP, 160-1000 kVA