[:en]
[:en]
[:]
[:en]The solution for:
• Data centers.
• Telecommunications.
• Health Sector.
• Service sector.
• Infrastructure.
• Industrial applications.
Advantages:
• Offers the highest performance on the market using VFI – Double Conversion Mode, the only UPS function that ensures complete load protection against all network quality problems.
• Highly efficient output independently tested and verified by an international certification body across a wide range of load and voltage operating conditions.
• Extremely high efficiency in VFI mode is provided by an innovative topology (3-level technology) developed for all Green Power UPS series.
Full rated power:
• No power degradation when delivering the latest generation of servers (driver or unity power factor).
• Real full power, according to IEC 62040: kW = kVA (unity power factor design) means 25% more active power compared to the older UPS.
• Also suitable for driving loads with a power factor below 0.9 without noticeable reduction.
Significant cost savings (TCO):
• Maximum energy savings thanks to 96% efficiency in true double conversion mode: 50% energy savings compared to the older UPS, offers significant energy savings.
• Performance up to 99% with FAST ECOMODE.
• UPS “self-help” with energy saving.
• Energy saving mode to improve overall performance in parallel systems.
• kW = kVA means maximum available power with the same UPS rating: no over-specification costs and consequently less €/kW.
• Advanced infrastructure cost optimization (sources and distribution), thanks to the high-efficiency IGBT rectifier.
• Battery life and performance:
– long-life battery,
– Very wide input voltage and frequency acceptance, without using a battery.
• EBS (Expert Battery System) charging management improves battery life.
• BCR (Re-Injection Capacity Battery) removes the limitations of using an additional load bank for battery discharge testing: it consists of re-injecting the energy stored in the batteries into other applications.
UPS model | Dimensions (WxHxD) | Weight |
---|---|---|
Delphis GP, 160 | 700 x 1930 x 800 mm | 470 kg |
Delphis GP, 200 | 1000 x 1930 x 700 mm | 490 kg |
Delphis GP, 250 | 1000 x 1930 x 950 mm | 850 kg |
Delphis GP, 320 | 1400 x 1930 x 800 mm | 980 kg |
Delphis GP, 400 | 1400 x 1930 x 800 mm | 1000 kg |
Delphis GP, 500 | 1600 x 1930 x 950 mm | 1500 kg |
Delphis GP, 600 | 2800 x 2060 x 950 mm | 2300 kg |
Delphis GP, 800 | 3510 x 2060 x 950 mm | 2800 kg |
Delphis GP, 1000 | 3910 x 2060 x 950 mm | 3850 kg |
[:en]The solution for:
• Data centers.
• Telecommunications.
• Healthcare sector.
• Service sector.
• Infrastructure.
• Industrial applications.
Advantages:
• Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that ensures total load protection against all mains quality problems.
• Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating conditions.
• Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power UPS ranges.
Full rated power:
• No power downgrading when supplying the latest generation of servers (leading or unity power factor).
• Real full power, according to IEC 62040: kW=kVA (unity power factor design) means 25% more active power available compared to legacy UPS.
• Suitable also for leading power factor loads down to 0.9 without apparent derating.
Significant cost savings (TCO):
• Maximum energy saving thanks to 96% efficiency in true double conversion mode: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill.
• Up to 99% efficiency with FAST ECOMODE.
• UPS "self-paying" with energy saving.
• Energy Saver mode for global efficiency improvement on parallel systems.
• kW=kVA means maximum power available with the same UPS rating: no overdesign cost and therefore less €/kW.
• Upstream infrastructure cost optimization (sources and distribution), thanks to high performance IGBT rectifier.
Extended battery life and performance:
– long-life battery,
– very wide input voltage and frequency acceptance, without battery use.
• EBS (Expert Battery System) charging management improves battery service life.
• BCR (Battery Capacity Re-injection) removes the constraints of using an additional load bank for the battery discharge test: it consists in re-injecting the energy stored in the batteries to other applications.
UPS Model | Dimensions (WxHxD) | Weight |
---|---|---|
Delphis GP, 160 | 700 x 1930 x 800 mm | 470 kg |
Delphis GP, 200 | 1000 x 1930 x 700 mm | 490 kg |
Delphis GP, 250 | 1000 x 1930 x 950 mm | 850 kg |
Delphis GP, 320 | 1400 x 1930 x 800 mm | 980 kg |
Delphis GP, 400 | 1400 x 1930 x 800 mm | 1000 kg |
Delphis GP, 500 | 1600 x 1930 x 950 mm | 1500 kg |
Delphis GP, 600 | 2800 x 2060 x 950 mm | 2300 kg |
Delphis GP, 800 | 3510 x 2060 x 950 mm | 2800 kg |
Delphis GP, 1000 | 3910 x 2060 x 950 mm | 3850 kg |
[:]
UPS Manufacturer | |
---|---|
UPS power | |
UPS Series |